Seeing the Whole Picture: Exploring Electroretinography (ERG) and the Potential of Global Assessment
Electroretinography |
What
is an Electroretinogram?
An electroretinogram (ERG) is a diagnostic test that is used to assess the overall
function of the retina. The retina is the light-sensitive layer of tissue at
the back of the eye. During an ERG test, small contact lens electrodes are
placed on the surface of the eye to detect the electric potential created by
retinal cells in response to light stimuli. The electroretinogram reflects
retinal function by measuring the summed electrical activity of different
retinal cell types, including photoreceptors and bipolar, amacrine and ganglion
cells. Specifically, an Global
Electroretinogram measures the electrical response of the retina to
light flashes or patterns. This helps the eye doctor determine if there are any
problems with the retina or visual pathway.
Types of ERG Tests
There are three main types of ERGs that can be done during testing:
- Full-field ERG: This test measures the overall retinal response from the
entire retina to a bright flash of light. It is useful for detecting disorders
that affect large areas of the retina such as retinitis pigmentosa.
- Multifocal ERG: In this test, small areas of the retina are stimulated
individually with a distinct bright flash while responses are recorded
simultaneously from multiple areas of the retina. This is useful for detecting
local retinal disorders likemacular degeneration.
- Single-flash or Flicker ERG: This test measures retinal responses to either a
brief flash or to a stimulus that flickers on and off at a steady frequency (30
flashes per second). It helps distinguish between outer retinal layer and inner
retinal layer problems.
Standard Protocol for an ERG
Most ERG exams follow a standard protocol to ensure consistent and reliable
results. Typically, the eye is darkened adapted for at least 10 minutes prior
to testing. This allows the retinal cells to become accustomed to the dark. A
non-invasive electrode is placed on the eye along with a reference and ground
electrode on the skin. The patient is presented with light flashes of
increasing intensity under computer control. The electrical retinal responses
are recorded by the electrodes. Both eyes are tested and the results are
compared to normative data. The entire exam usually takes 30 to 45 minutes to
complete.
What the ERG Results Can Indicate
By analyzing the amplitude (height or strength) and latency (timing) of the ERG
waveforms, eye doctors can understand how well the different retinal layers are
functioning. Abnormalities in the ERG reading can help point to various
posterior eye diseases and conditions. For example:
- Reduced or absent a-waves often suggest a problem with the photoreceptors
(rods and cones) and may indicate conditions like retinitis pigmentosa.
- Reduced b-wave amplitude is typical of inner retinal layer diseases like
diabetic retinopathy or optic nerve problems affecting retinal ganglion cell
function.
- Prolonged or delayed ERG latency times may indicate a retinal pathology
affecting the speed of neural transmission in the retina.
- Overall amplitude reduction across all waves could signal a global retinal
disorder such as retinitis pigmentosa.
Investigating Global Retinal Function
As retinal diseases often affect vision globally across both eyes, researchers
have studied ways to analyze retinal responses over a wider retinal area using
techniques like the global flash ERG. This test involves simultaneously
illuminating both eyes together with a widespread blanket of light rather than
isolated spots or flashes. The electrical activity is picked up from the
corneal surface. Such global ERG testing may provide new insights into treating
and monitoring retinal conditions that impact sight bilaterally.
Global ERG Advantages and Applications
There are several potential advantages to the global ERG approach:
- It allows for assessing overall binocular retinal function as the two eyes
are stimulated together as normally occurs during natural vision. This more
closely mimics real-world visual scenarios.
- The globally derived ERG waveforms tend to have higher amplitudes since they
capture the summed retinal activity from two retinas simultaneously. This
enhances diagnostic accuracy.
- It could provide a more efficient technique for monitoring retinal function
and treatment efficacy in hereditary retinal dystrophies that affect both eyes
like retinitis pigmentosa.
- The global ERG may be useful as an objective method to evaluate new retinal
prosthetic or gene therapy trials that aim to restore vision bilaterally. Any
treatment effects across both retinas could register on global ERG recordings.
- With further standardization, the global ERG protocol may eventually translate
to a quicker bedside or office-based test to estimate retinal health compared
to traditional full-field ERGs requiring darker settings.
Overall, the global ERG methodology shows promise as a supplemental approach
worth additional research to optimize its role in investigating binocular
vision problems and developing new retinal disease therapies. As technology
continues enhancing our understanding of retinal electrophysiology, new ERG
techniques will keep emerging to benefit patient care.
Get more insights on Global Electroretinogram